Reports until 09:07, Wednesday 13 May 2026
H1 SPI
jeffrey.kissel@LIGO.ORG - posted 09:07, Wednesday 13 May 2026 (90223)
SPI Installation Handles Fit Check
J. Kissel
ISIK Transceiver Assembly D2400107-v5
ISIK Installation Handle Assembly D2500215-v2

In prep for moving the old version of the SPI pathfinder's ISIK transceiver (D2400107-v4) with CVM100 mounts to the side, I assembled and fit-checked the (Class-B) ISIK Installation Handle Assembly D2500215. It fit! The only detail that required clock cycles was understanding which hardware went to which hole, so I made some redlines and posted them to D2500215-v2.

Attached are pictures before moving ye ol' 'board.

Nice work ANU!
Images attached to this report