ISS work restarts

Restored the alignment sliders for IM2 and IM3 back to Monday values ([IM2P, Y] =[765, -187.7], [IM3P, Y]=[-560.7, 320]).

Measured the flashes. Chose the flash that gave the MC2 trans sum maximum power, which in general agreed with IM4 trans sum max but didn't with ISS QPD nor array PD inner sum nor outer sum. 

Anyway, 

PIT and YAW numbers were after normalization divided by (seg1+2+3+4), not by SUM, so there's a small difference but that doesn't matter at this point.

IM4 TRANS and ISS QPD PIT and YAW are broadly in agreement with Jenne's alog 90206 i.e.

I haven't compared the ISS Outer SUM with March 2026 when IMC was locked with 2W. Somebody check please. We'll go into chamber and start checking the beam path.

Comments related to this report
elenna.capote@LIGO.ORG - 13:46, Wednesday 13 May 2026 (90232)

On March 11 when we locked the IMC at 2 W, the outersum was 0.062. Today, I measured the outersum flashes (relative to the dark noise) to be 0.031, with 0.18 W input. This means our alignment into the ISS has improved relative to March.