restart h1lsc model

Following the DAQ restart to service the h1sushtts model change, I noticed that h1lsc DAQ status changed to 0x2000 (new ini file). I pressed the "DAQ Reload" button on h1lsc which cleared the error, and then realized  that there is most probably a mismatch between the lsc model and its INI file. True enough, the model was started on Tue 17th but the model was changed and a "make install" issued Wed 18th. At this point the lsc data is most probably corrupted in the frame.

I restarted the h1lsc model to bring the software and the INI file back into synchronization.

Comments related to this report
christopher.wipf@LIGO.ORG - 11:57, Thursday 19 December 2013 (9028)

Mea culpa.  The LSC model was rebuilt to fix the channel names of its antiwhitening switches, but I postponed the restart since the model was in use last night.  Thanks for taking care of it.