BBS SUS Cage Aligned to ISI

R. Crouch, B. Weaver, I. Abouelfettouh, J. Oberling, R. Thompson

Today we placed and aligned the BBS SUS cage on the WBSC2 ISI.  In the morning we rough placed the SUS, and thought we had done a really good job on the first attempt.  However, that was fed by a misread of how the Build/Inspect function in PolyWorks, well, works, and upon doing a more thorough measurement (directly measuring a constraining plane to inform SMR radius compensation instead of letting PolyWorks handle it automatically) we found there was a position and rotation error to the cage.

In the afternoon we moved the SUS cage around until things looked really good.  We were well within our +/-1.0 mm XYZ tolerance, but once the SUS had been fully dog clamped to the ISI things shifted (as they do).  In this case, it was roughly 0.5 mm in the +Y direction.  All of our measurement points except one are within tolerance, so we called this good enough for SUS cage placement.  To end, Ryan and I measured the circle that's defined by the lower section of the Figure 8 (the round section of the SUS cage that surrounds the BBS) on both the HR and AR sides of the cage.  The first attachement shows the position deviations of the 4 points we used for cage placement/alignment and the current position of the HR and AR Figure 8; all except the Y axis position of 1 point are within our tolerance.  The second attachment shows the rotation of the SUS cage w.r.t. the ISI; the angles listed are in degrees and are measured from the positive axes they are associated with (so X Ang is measured from the +X axis).  These 2 lines show that the SUS cage is rotated roughly 400 - 500 µrad CCW (top-down view) from nominal.

Next up is to set up a total station looking at the AR face of the BBS to precisely align the optic to the ISI.

Images attached to this report