IMC alignment investigation continues (Elenna, Rahul, Keita)

Starting with yesterday's alignment, we tried to move the beam spots on IFI input baffle (using IM1), IFI output baffle (using IM2) and the baffle in front of IM4 (using IM3).

We had to make a huge change in all of the optics used: IM1 yaw: -500 urad, IM2 yaw: -900 urad, IM3 yaw: -720 urad.

Forgot to measure PIT/YAW position of IM4_TRANS (and we cannot trend it as we need fast data of segments) but the beam was on IM4_TRANS with almost full IM4_TRANS_SUM.

IMs didn't rail but this is clearly NOT the right way to move. Instead, what we need seems to be to shift the beam position on MC3 by a few mm in -X-Y direction.

We didn't bother to move PRM nor IM4 so the IFO REFL was again misaligned badly.

(One thing to note is that with this drastic change in the input alignment, the beam was still hitting the IM4 TRANS but not ISS QPD. However, just by turning IM3 we were able to regain the beam on ISS QPD. Now I'm fully confident that, whatever alignment we end up having after pumping down, as far as the beam is on IM4 TRANS, we can find the beam on ISS QPD by scanning IM3 (and IM2 if necessary) and slowly walk the beam using the picos to have a good alignment in the ISS path.)

We also measured the beam position (both height and Y position relative to the ideal beam path measured at specific X coordinate) to better understand the IMC beam. Numbers are to follow, but the gist is that the beam position is good (i.e. likely centered) on MC3 but is off in -Y direction by 3mm or so on MC2 even though MC TRANS is close to center.

So, for tomorrow:

My guess is that the beam has been (at least very close to) clipped by some of the IO baffles for a long time, and the above practice is to see if there is an alignment where the beam is at least not clipped.

Comments related to this report
elenna.capote@LIGO.ORG - 08:37, Wednesday 20 May 2026 (90293)

Just want to add here that I undid all slider changes we made on Tuesday, specifically these: "IM1 yaw: -500 urad, IM2 yaw: -900 urad, IM3 yaw: -720 urad"

While these changes did not saturate the suspensions, IM2 and IM3 were very close to saturation, and we would not want to operate with them at those positions.