kyle.ryan@LIGO.ORG - posted 14:52, Thursday 19 December 2013 (9032)
Changed IP5's controller settings
Found IP5 not pumping effectively due to improper settings -> nominal settings for nominal pressures not -6 torr environment -> changed "Imax" value from 10mA to 200mA and "Pmax" value from 50watt to 200watt -> Ok now