Displaying report 1-1 of 1.
Reports until 10:00, Tuesday 02 June 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 10:00, Tuesday 02 June 2026 (90358)
h1suslo12 model update - COIL2M1DAC and BIO IPC receivers/senders back in

Yesterday I made some changes to the h1suslo12 model(before, after). We were now done with the BOSEMs on the BBSS, so we needed the BBSS model to be able to drive to the DAC for M1 so we could test the QOSEMs. We also needed to be able to switch the BIO on the BBSS, so we also needed to connect the BIO senders and receivers back up to be able to communicate with MC2, which controls the BIO switching for the b2h34 models.

To be able to run this updated model, we would also need to stop the h1susbs model so there wouldn't be mulitple sets of channels trying to write to the same DAC.

Erik and Jonathan (90422) helped with stopping h1susbs, and with building and restarting h1suslo12.

 

Images attached to this report
Displaying report 1-1 of 1.