david.barker@LIGO.ORG - posted 17:46, Thursday 19 December 2013 (9040)
SUS and ASC model changes to complete IPC install

Sheila and Dave.

Sheila made changes to the following SUS models to add missing IPC channels (the existing models had place-holders for the IPC channels).

h1susbs, h1susetmx, h1susetmy, h1susim, h1susitmx, h1susitmy, h1suspr3, h1sussr2, h1sussr3 and h1sussrm. The model h1susprm had a simple text edit to clean it up.

We discovered an RFM0-RFM1 error on the h1asc and h1susetmy models. RFM0 is the X-Arm and RFM1 is the Y-Arm. I hand edited the H1.ipc file to change ETMY ASC PIT and YAW from RFM0 to RFM1.

All models were compiled and installed, the DAQ was restarted.

IPC data from ASC to SUS-ETMX and SUS-ETMY were tested to verify the RFM0,1 settings were correct.