Displaying report 1-1 of 1.
Reports until 00:32, Friday 05 June 2026
H1 SEI
arnaud.pele@LIGO.ORG - posted 00:32, Friday 05 June 2026 (90495)
CRS progress June 4 - 1 CRS balanced and x2 HOQIs tested

Alexandra, Shoshana, Arnaud, Fil, Dean (remote)

Today we completed the balancing of the CRS with a period of 61s (or 16.4mHz, which is our target frequency), aligned and tuned the HOQIs (with >75% fringe visibility) and connecterized the picomotor to the mighty mouse connector. Tomorrow, after verifying the balancing and alignments have not changed, we will mount the HOQIs to the CRS, which will complete this first assembly. 

In detail : 

Note1: We did break a set of flexures during balancing today (SN 18 and 11) 
Note2: We could not get good fringe visibility on a 3rd HOQI (max 60%) we tested. We will have to get back to this one.
Note3: The Right HOQI has a PD wire that seem to have been pinched during assembly (see last photo). This doesn't seem to be an issue, we will just have to be careful when routing that it doesn't touch the baseplate.