Richard, Filiberto, Daniel
We tested the photodiodes and they seem to be all working. There was a problem with the ordering as seen by the slow controls system. This is fixed now, and the order has changed relative to an hour ago. 1 and 3 swapped, and 2 and 4 swapped. This also brings the order as shown by the medm in agreement with the AOS drawings. We also added the hooks for the binary outputs to adjust the gain. However, these won't be activated until we receive the binary EP module. For now the gain adjust on the medm does NOT work and needs to be done with a breakout board directly at the DB37 of the PD amplifier.