SPI Pathfinder Mass Budget
J. Kissel, S. Koehlenbeck

Here's the mass of the SPI pathfinder's ISIK transceiver that will be suspended on HAM3.

10.958 [kg] :: Fully assembled ISIK Transceiver (D2400107)
    - no installation handles
    - no baffle bracketry
    - sensor/actuator cabling draped to the side

0.898 [kg] :: Fully assembled portion of in-vac cabling that will be suspended on Stage 1 of HAM3 ISI
    - includes cable table brackets
    - excludes QTY 2x D25 to D25 signal bus cables that span ST1 to ST0 to Feedthru.

0.703 [kg] :: Fully assembled portion of in-vac fiber optic cabling that will be suspended on Stage 1 of HAM3 ISI
    - 0.570 [kg] :: QTY 2x will be suspended so expect 2x0.285 = 0.570 [kg]
       . 0.285 [kg] :: QTY 1x Fiber spool (what was actually measured, rather than two)
       . Most of the optical fiber, plus wont-be-there fiber mating sleeve and cap
    - 0.133 [kg] :: QTY 2x Fiber spool assembly feet and installation hardware: 

12.599 [kg] :: Total suspended mass.

All this mass will be on the -X side wall of the ISI, below the optical table, as shown in D2400103.

We have not measured the mass of any component of the ISIK shroud assembly D2400106.
Images attached to this report