Displaying report 1-1 of 1.
Reports until 16:31, Thursday 04 June 2026
H1 SPI
thomas.shaffer@LIGO.ORG - posted 16:31, Thursday 04 June 2026 - last comment - 11:59, Tuesday 09 June 2026(90493)
HAM2 SPI ISIJ and below table

When I hammered the below table "beard" baffle on May 26 (alog90335), something wasn't correct with the way I saved the data or my configuration or something else. Either way, Jeff and went in today and hit that as well as the SPI ISIJ assembly with and without the cylindrical shroud (D2500030). Preliminary results are looking much better, so I'll clean those up and post them soon with a whole writeup.

Comments related to this report
thomas.shaffer@LIGO.ORG - 15:57, Friday 05 June 2026 (90510)

J Kissel, T Shaffer

All plots are in the accelerometer axis as defined below for each test. The measurement numbers were just for my own organization within the B&K software.

ISIJ

We did this in two stages, one set with the D2500030 cylindrical shroud and one set without. The accelerometer was mounted on a bolt hole below the ISIJ on the HAM face (photo).

Hit location (on shroud or reflector) With Shroud Without Comparison plots
-Y IFO (+Y acc) Meas 5 Meas 9 Attachment 1
+Z IFO (-Z acc) Meas 6 Meas 10 Attachment 2
-X IFO (+X acc) Meas 8 Meas 11 Attachment 3

The shroud has clear resonant peaks at 137, 196, 314Hz. It was ultimately decided to leave this piece off for now.

 

Below Table Baffle 

Measuring the central below table baffle (D2600042) with the accelerometer mounted on the L bracket (D1700264) on the outermost bolt hole (photo). The accelerometer axis X,Y,Z = IFO -Z,Y,X.

    Meas 1 - First hit IFO +X (+Z acc) bottom of L bracket - attachment 4

    Meas 2 -  hit in -Y IFO (-Y acc) on L bracket - attachment 5

    Meas 3 - hit in +Z IFO (-X acc) L bracket bottom. Note that the bracket is tilted in the IFO -X direction. - attachment 6

There is a small peak at 87Hz.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:59, Tuesday 09 June 2026 (90544)
Here's video evidence of the resonance -- see https://www.youtube.com/watch?v=bgA-cGWJSbg.
(Video is sadly too large for posting to aLOG.)
Displaying report 1-1 of 1.