Erik, Oli
Now that we don't need the BSFM model anymore, we can move the BBSS model over into h1susbs (it was temporarily on h1suslo12). It's been committed to svn as r35313.
I moved the BBSS model from h1suslo12 over to h1susbs. Then I made some more changes to get everything up and running. Both h1susbs and h1suslo12 were successfully able to build on h1build.
Things updated/added/removed:
h1susbs (r35313) - moved what was in h1suslo12 at the time over to h1susbs and then made the following changes:
- Changed dcuid from 188 (h1suslo12) to 31 (h1susbs)
- Changed name of BBSS block from BBSS to BS
- Changed top level channel names from BBSS to BS
- Added in PCIE senders and receivers for ISC, Dither, SUPOINT, IFOTRIG, and CALCS
- Had a bug where the bus selectors weren't naming themselves properly and so rcg was getting confused, but Erik figured out the issue and we just had to edit the new bus names
BBSS_QOSEM_MASTER (r35312):
- Added M3_WIT_{L,P,Y} to the DAQ channel list (committed to svn as r35296)
- Removed the USER DACKILL because we don't need it anymore (committed to svn as r35312)
h1suslo12 (r35318):
- Reverted back to what it looked like after r34977 (see 90358)