Reports until 16:57, Wednesday 10 June 2026
H1 SUS
oli.patane@LIGO.ORG - posted 16:57, Wednesday 10 June 2026 (90579)
IM1-4 TFs looking good after in-chamber work

Took some transfer functions of IM1, IM2, IM3, and IM4 now that HAM2 work is basically over. They all look good, even though a couple degrees of freedom (specifically L) don't have the best coherence due to not being able to drive too much in air without saturating

Settings
- ISI Locked
- DAMP OFF
- OPTICALIGN OFF

IM1
Data
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Data/2026-06-10_2200_H1SUSIM1_M1_WhiteNoise_{L,P,Y}_0p02to50Hz.xml
Results
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM1/SAGM1/Results/2026-06-10_2200_H1SUSIM1_M1_ALL_TFs.pdf
r13029

IM2
Data
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/SAGM1/Data/2026-06-10_2210_H1SUSIM2_M1_WhiteNoise_{L,P,Y}_0p02to50Hz.xml
Results
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM2/Results/2026-06-10_2210_H1SUSIM2_M1_ALL_TFs.pdf
r13030

IM3
Data
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/SAGM1/Data/2026-06-10_2210_H1SUSIM3_M1_WhiteNoise_{L,P,Y}_0p02to50Hz.xml
Results
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM3/Results/2026-06-10_2210_H1SUSIM3_M1_ALL_TFs.pdf
r13031

IM4
Data
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/SAGM1/Data/2026-06-10_2250_H1SUSIM4_M1_WhiteNoise_{L,P,Y}_0p02to50Hz.xml
Results
/ligo/svncommon/SusSVN/sus/trunk/HAUX/H1/IM4/Results/2026-06-10_2250_H1SUSIM4_M1_ALL_TFs.pdf
r13032

Non-image files attached to this report