Reports until 08:35, Friday 12 June 2026
H1 General (CDS)
anthony.sanchez@LIGO.ORG - posted 08:35, Friday 12 June 2026 - last comment - 12:52, Friday 12 June 2026(90604)
Friday morning Ops shift report.

TITLE: 06/12 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: MAINTENANCE
    Wind: 13mph Gusts, 9mph 3min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.08 μm/s 
QUICK SUMMARY:

It was requested that I try to trend the Oplevs this morning, but the BS SUS screen is full of white boxes that claim their channels don't exit when NDscoped. Tagging CDS. 

I did however find the Input Pointing Trends button which gave me the following: 
IMs 
BSCs (No motion on the BS channels here though which is some SUS-picious BS)
MCs
PRMs

 

Images attached to this report
Comments related to this report
anthony.sanchez@LIGO.ORG - 09:30, Friday 12 June 2026 (90606)

So Dave and I talked a bit about the BS  MEDM page VS the BBSS(temp) which Does Indeed have trendable oplevs..... but.... once again there is no motion on those channels either.

 

Images attached to this comment
anthony.sanchez@LIGO.ORG - 12:52, Friday 12 June 2026 (90608)

I was able to get this H1:SUS-BS_M3_OPLEV data from the last day the NDS2 server. 

Images attached to this comment