Reports until 12:47, Monday 15 June 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 12:47, Monday 15 June 2026 (90617)
File changes to get BBSS up and running as h1susbs

h1susbs is now fully running the BBSS and everything that was previously on the h1suslo12 model was moved over. The channels that were previously called SUS-BBSS are now called SUS-BS. Old SUS-BBSS data can still be grabbed by using nds2.

I unpaused the BS guardian and took the suspension to DAMPED. It is damping.

/opt/rtcds/userapps/release/cds/h1/medm/SITEMAP.adl
r35324

- Removed BBSS(temp) and updated link for BS

/opt/rtcds/userapps/release/sus/h1/medm/susbs_overview_macro.txt
r35325

- Copied over susbbss_over_macro.txt and updated optic name and dcuids

/opt/rtcds/userapps/release/sus/common/medm/bbss/SUS_CUST_BBSS_QOSEM_OVERVIEW.adl
/opt/rtcds/userapps/release/sus/common/medm/bbss/SUS_CUST_BBSS_M3_OPLEV.adl
r35327

- Removed temporary 'lo12' filled in optic names and replaced with $(optic)

/opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSLO12.txt
/opt/rtcds/userapps/release/sus/h1/filterfiles/H1SUSBS.txt
r35326

- Copied over previous BBSS filter files into H1SUSBS (with name change from BBSS -> BS)
- Committed updated H1SUSLO12 filter file (which has no filters loaded, which is correct)

/opt/rtcds/userapps/release/sus/h1/burtfiles/h1susbs_down.snap
r35329

- Copied opt/rtcds/lho/h1/target/h1suslo12/h1suslo12epics/burt/safe.snap over to /opt/rtcds/userapps/release/sus/h1/burtfiles/h1susbs_down.snap, which due to symlinks gets linked over to opt/rtcds/lho/h1/target/h1susbs/h1susbsepics/burt/safe.snap
- Loaded BS sdf from safe.snap and 'reverted' changes to get the model to put in the correct settings