Reports until 16:58, Monday 15 June 2026
H1 CDS
david.barker@LIGO.ORG - posted 16:58, Monday 15 June 2026 (90622)
h1susb2 model returned to h1susb2h34 and runs the BS model, h1suslo12 returned to LO12 duties

WP13294 h1susbs running BBSS model, restore h1suslo12

Erik, Oli, EJ, Jonathan, Dave:

h1susbs was returned, via puppet, to h1susb2h34's model list. Oli created a new h1susbs, with the old BSFM model replaced with the BBSS model which had been running on h1suslo12. This was not a straight move, changes were also made including restoring all the IPC channels.

h1suslo12 was returned to LO12 duties, restoring this model to what it was before it became the temporary BBSS model.

Because DAC channels were being swapped between models, and the DAQ needed to send a new model's data block, we decided to fence and reboot h1sush2h34 to make these changes.

Jonathan restarted the DAQ. Both broadcasters needed a BBSS to BS name change.

CDS is once again running with zero IPC errors.