HAM2 Doors Installation

(Randy, Jordan, Jake, Owen, Travis, Gerardo)

Both doors were installed on HAM2, no issues to report.  The usual dance, take one door off, to then move the cleanroom to be able to remove the other door, thank you all for the help moving this cleanroom.  

There are some pecularities that we like to note about the doors, we noted some rust on both flanges of HAM2 -Y and +Y, and some embeded particulate on some of the O-rings, metal type all over, the particles were removed with a clean wipe, however there was a "green" fiber on the +Y door O-ring, outer O-ring, around 11 O'clock, this fiber runs with the seal and not across, so we did not poke at it.

Then we connected an aux cart to the annulus system, and started the pump down, we will add second aux cart to help with pump down.

Next, we like to inspect the viewports on this chamber, but this job is going to require laser safe and no table near the door.  We did note something on the central high quality viewport and we like to take a closer look at it.