SPI install update - day 6

Jennie W, Jeff K, Josh F, TJ S,

Summary: SPI interferometers aligned, shroud installed successfully. One stray beam and possible clipping on shroud to investigate/deal with but otherwise all problems were solved. Obligatory success photo taken by Josh.

Today we:

 

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 10:08, Monday 22 June 2026 (90690)

More details regarding the baffle installation:

When placing the below table baffle brackets, there was a ballast mass baffle (D1700262) that was blocking the angle bracket for the furthest -Y bracket. The bracket could not slide under the ballast mass baffle (bmb), so we decided to move the bmb in the +Y direction a few inches and I had to loosen the baffle panel within the feet to slide it up a few mm and then reclamp. This allowed the bracket to slide under the baffle just to the side of the feet, but the move partially exposed a corner of the shiny ballast mass stack.

The lower baffle shroud that covers the breadboard needed the fiber spools to be moved. We moved them over one set of bolt holes, but they are quite close to chamber edge, I'd guess around 1/2". Jeff then centered the two aperatures to the SPI beam, and we called it good. We still need to B&K the whole area.

Images attached to this comment
jennifer.wright@LIGO.ORG - 17:46, Monday 22 June 2026 (90699)

Just did an 8 hour trend of the fiber power monitor channels for REF and MEAS channels (left two plots) and the optical lever QPDs (right two plots) to check whether we expect variations on the order of ~2V on the QPDslike we saw on Thursday before and after baffle installation.

From this trend the power appears to drift more than this for two hours after unshuttering the laser (around 15:56 UTC), but once it reaches a steady state both QPDs were only drifting by 1V and the fiber power input monitor PDs by 1V or less.

Conclusion: I think we would have seen a dramatic power drop on Thursday when we installed the shroud, that I would expeact to have been much larger than the trends I saw today.

Images attached to this comment
jeffrey.kissel@LIGO.ORG - 13:47, Tuesday 23 June 2026 (90713)
Note mentioned in the summary of activities in the main entry -- per LHO:90667, we re-installed all the ballast or balance mass discussed during this 2026-06-18 day's session. See attached "after" picture.
Images attached to this comment
brian.lantz@LIGO.ORG - 09:40, Friday 03 July 2026 (90893)EPO

Here's another picture of the SPI breadboard on HAM3 prior to the baffle installation. Photo credit is ?? maybe Jeff?