CP1 Cooldown Update

(Jordan, Owen, Jake, Gerardo)

The cryotrap cooldown continues, we continue to pump on the cryotrap volume with a turbo pump, the turbo is backed with a SS500 aux cart.

Small changes were the removal of the calibrated leak from the RGA tree, along with the removal of other components in preparation to install an incoming small ion pump next week.

Current pressure in the cryotrap volume is 7.38X10-10 Torr.

 

Images attached to this report
Comments related to this report
jordan.vanosky@LIGO.ORG - 16:59, Monday 29 June 2026 (90814)VE

Jordan, Jake, Owen

The RGA tree was removed and replaced with the dedicated 75 l/s Starcell ion pump and a pumpdown port for the pump tree.

All flanges were helium leak tested, no He signal above the leak detector background were found. (~1.5E-10 Torr-l/s)

Volume is currently being pumped by a small aux cart, and the ion pump will be powered on tomorrow. The volume will then be introduced to the cryopump volume once the pump pressure reaches ~E-9 Torr on ion pump alone.

 

 

Images attached to this comment
gerardo.moreno@LIGO.ORG - 05:22, Friday 10 July 2026 (90981)VE

Update for CP1.

Last Tuesday 7/7/26, Jordan removed the turbo pump and introduced the small ion pump to the CP1 vacuum volume, this closed the warm up of CP1.  Attached plot of small ion pump controller and pressure reported by the cold cathode at CP1.

Images attached to this comment