TITLE: 06/29 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:
BBSS closeout tasks in-chamber, lvea furniture-moving, SQZ work today. ITMy exhibited rung up motion in the afternoon--people in the next chamber over could see ITMy swinging!
LOG:
- 1415-1638 Technical cleaning
- 1440 brought out trash & then off to check LSB; will head back into lvea for another round ( [kim]
- 1510-1638 back to lvea
- 1507-1529 Ameristat search (betsy)
- 1518-1529 Chat with Betsy (randy)
- 1532-1538 isolating aux cart for ham1&2 annulus (jordan)
- 1533-1613 redress SPI cables at HAM3 on +Y(jeff)
- 1623-1633 fixing a squished cable (jeff)
- 1545-1707 craning @West Bay (randy)
- 1610-1854 FARO for BBSS (ryanC.jason)
- 1648-1756 BSC2 unlock hepi to see if everything looks good between locked/unlocked (jim.mitch)
- 1651-1808 BBSS in-chamber checklist items (ibrahim.betsy)
- 1741-1935 HAM7 table work (camilla)
- 1802-1935 SQZT7 table work (ryanS)
- 1812 certication paperwork check at FCES (bubba)
- 1911-1919 running laptop to SQZ crew (sheila)
- 1932 Received monthly automated alert test for sirens (phone call)
- 1947 craning Aluma-lift over x-arm (randy)
- 2002-2251 In-chamber BBSS closeout---baffle install, removed items under the floor panels, and assisted with installing ISI lockers (betsy.ibrahim.elena)
- elena & betsy came out earlier.
- 2014 ITMy transfer functions (rahul)
- 20:26 Betsy phoned about big motions on ITMy visible by eye from another chamber!
- 2121 SD OSEM took the big step down to -400 (from -90)
- Dave noticed noise at 2117
- Oli & Elenna have been investigating
- 2038-2138 viewport removal for a blank at HAM5 (travis)
- 2100 seismometer testing on x-arm (shrey.carlos)
- 2103-2155 PEM ADC(dave)
- 2100-2321 Ey trip for Beckhoff hepi upgrade; ISI taken to Damped_HEPI_OFFLINE + (patrick)
- 2104-2340 cp1 ion pump install (jordan,jacob,owen)
- 2106 BSC2 isi floating, locker install, & then ISI balance (jim.mitch)
- 2112-2324 SQZT7 table work (ryanS.camilla.sheila)
- sheila joined them for a bit.
- 2133 HAM5 ISI WD tripped(restored to isolated at end of shift)
- 2234 HAM4 ISI WD tripped (restored to isolated at end of shift)
- 2236-2337 HAM3 viewport adapter install (travis.shoshonna)
- 2236-2251 HAM2 dustmonitor cleaup (ryanC)
- 2332-2342 Setting up FARO for tomorrow (jason)