Displaying report 1-1 of 1.
Reports until 11:13, Monday 29 June 2026
H1 SPI (CDS, SEI, SPI, SYS, VE)
jeffrey.kissel@LIGO.ORG - posted 11:13, Monday 29 June 2026 - last comment - 11:35, Monday 29 June 2026(90792)
2026-06-29 H1ISIH23 HAM3 ISIK Transceiver Cabling Re-dressed
J. Kissel

This morning, I re-installed the H1SPIH23 pathfinder's photodiode and picomotor cable-table-brackets (CTBs) that had been temporarily moved to upgrade the Corner 1 H1 capacitive position sensor (see LHO:90791), and re-dressed the cabling cable clamps.

As mentioned in passing in LHO:90750 the CRS team will now consume the "spare" SPI_HAM3_004 quadrupus leg, that's J2 of the S2500513 instantiation of D2400342, which manifests as CH8 on the TCSY_C02, Controller 10, PICO G picomotor controller driven by the Corner 2 ECAT chassis -- which shows up on the H1SYSCSAUX computer's SDF system. So this has been routed in the +X direction and up in +Z to the table top on the +Y corner.

I'll post pictures of all the re-dressing in the comments so I can better caption them.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 11:14, Monday 29 June 2026 (90793)SEI
Routing of the J2 leg of the D2400342 picomotor cable to the +Y corner of the table top.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:15, Monday 29 June 2026 (90794)
Big picture images of the ST1 portion of the cable dressing on the Corner 1 sensor/actuator hatch.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:17, Monday 29 June 2026 (90796)SEI
Zoom of how the 2x D25 cables are routed with a nice soft s-curve as the cables jump from the ST1 suspended stage to ST0 support stage.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:25, Monday 29 June 2026 (90797)CDS, SYS
Zoom of Cable Table Bracket 1 (CTB-1), which collects 
    - (1st Floor) the D25 end of the D2400343 PD concentrator cable SPI_HAM3_[031-034] (hidden from view), and 
    - (2nd Floor) the D25 end of the D2400342 quadrupus picomotor cable SPI_HAM3_[001-004]
and sends them into
    - (1st Floor) the ST1 end of 28 AWG D25 cable SPI_HAM3_014
    - (2nd Floor) the ST1 end of 22 AWG D25 cable SPI_HAM3_012
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:31, Monday 29 June 2026 (90798)
Zoom of Cable Table Bracket 2 (CTB-2), which collects 
    - (1st floor) IFO MEAS A/B single-element PDs' duopus
    - (2nd floor) IFO REF A/B single-element PDs' duopus
and sends them into
    - (1st floor) Cable D, i.e. SPI_HAM3_032 of the D2400343 PD concentrator.
    - (2nd floor) Cable E, i.e. SPI_HAM3_031 of the D2400343 PD concentrator.
Images attached to this comment
jeffrey.kissel@LIGO.ORG - 11:35, Monday 29 June 2026 (90800)
Zoom of Cable Table Bracket 3 (CTB-3), which collects 
    - (1st floor) OL ISIK QPD B 
    - (2nd floor) FBR PWR REF/MEAS single-element PDs' duopus
and sends them to 
    - (1st floor) Cable B, i.e. SPI_HAM3_034 of D2400343 PD concentrator
    - (2nd floor) Cable C, i.e. SPI_HAM3_033 of D2400343 PD concentrator
Images attached to this comment
Displaying report 1-1 of 1.