Restored EY CP7 PID controls following computer reboot

Following the reboot of h0vacey at 15:37 this afternoon the CP7 PID fill parameters needed to be reset. Using the values in h1vacuumsdf's safe.snap file, I ran the following caput commands as user vacuum on zotvac0

caput H0:VAC-EY_CP7_400_LLCV_CTRL PID
caput H0:VAC-EY_CP7_400_LLCV_MAN_POS_PCT 8.80000000000000000000e+01
caput H0:VAC-EY_CP7_400_LLCV_PID_CYCLE_TIME 1.00000000000000000000e+04
caput H0:VAC-EY_CP7_400_LLCV_PID_ITERM_MAX_LIM 2.00000000000000000000e+01
caput H0:VAC-EY_CP7_400_LLCV_PID_ITERM_MIN_LIM -2.00000000000000000000e+01
caput H0:VAC-EY_CP7_400_LLCV_PID_KI 1.00000000000000008180e-05
caput H0:VAC-EY_CP7_400_LLCV_PID_KP 6.00000000000000000000e+00
caput H0:VAC-EY_CP7_400_LLCV_PID_OFFSET 8.00000000000000000000e+01
caput H0:VAC-EY_CP7_400_LLCV_PID_OUT_DEAD_BAND 0.00000000000000000000e+00
caput H0:VAC-EY_CP7_400_LLCV_PID_OUT_MAX_LIM 1.00000000000000000000e+02
caput H0:VAC-EY_CP7_400_LLCV_PID_OUT_MIN_LIM 2.50000000000000000000e+01
caput H0:VAC-EY_CP7_400_LLCV_PID_SETPT_PCT 9.20000000000000000000e+01
caput H0:VAC-EY_CP7_XV400_LLCV_ENABLE_CTRL Enable
caput H0:VAC-EY_CP7_LT400_PUMP_LEVEL_MA_SMOO 9.98999999999999999112e-01
 