Reports until 13:03, Thursday 09 July 2026
LHO VE (VE)
travis.sadecki@LIGO.ORG - posted 13:03, Thursday 09 July 2026 - last comment - 17:32, Friday 17 July 2026(90967)
HAM7 A1F1 and A2F1 viewports removed and blanked off

Per FRS 38164, the unused viewport located at A1F1 and A2F1 on HAM7 have been removed and blanked off.  These viewports are being moved to HAM3, so serial number, etc. will be recorded in a separate aLog.

Images attached to this report
Comments related to this report
jordan.vanosky@LIGO.ORG - 08:45, Friday 10 July 2026 (90983)VE

The HAM3 A1F3 viewport was a coated ZV-800 which had many small scratches on the vacuum side of the window, we replaced this with the HAM7 Uncoated ZV-800 SN R136. The A1F4 viewport was a D1100999 High Quality viewport (O-ring sealed), it was determined that this port no longer needs the high quality viewport and was then swapped with the other removed viewport from HAM7 (ZV-800 Uncoated R134).

Per Betsy, both of these ports are only used for views inside the chamber, so Uncoated viewports could be used to replace the two coated viewports which were removed.

The viewports removed from HAM3 will be inspected on the bench and if they pass inspection criteria they will be put into spares inventory.

Images attached to this comment
melina.fuentes-garcia@LIGO.ORG - 17:32, Friday 17 July 2026 (91098)

After confirming with Jordan, the comment above has a small typo: The viewport that came off of HAM7 port A2F1 is recorded in LHO's inventory lists (LIGO-T1200220 and LIGO-E2400096) as SN R146 (not R136 as listed above).

As a visual indicator of these swaps: 

HAM7 A2F1 SN R146 → (removed and moved to) → HAM3 A1F3

HAM7 A1F1 SN R134 → (removed and moved to) → HAM3 A1F4