Displaying report 1-1 of 1.
Reports until 12:09, Thursday 09 July 2026
H1 SUS (SUS)
kenneth.cardona@LIGO.ORG - posted 12:09, Thursday 09 July 2026 - last comment - 18:10, Thursday 09 July 2026(90964)
BBSS cross coupling transfer function comparison between L1 and H1

Ken, Preeti, TJ

We've made transfer functions to see and compare the level of cross coupling between P and Y at both sites for the top stage of BBSS. The L1 traces were rescaled to match the H1 magnitude for the PtoP comparison at 0.1Hz. The scaling factor was 3.72. This was done to compensate for the DAC differences between the sites. All of the L1 traces were multiplied by this scale factor. All plots are found in the attached PDF. 

Non-image files attached to this report
Comments related to this report
kenneth.cardona@LIGO.ORG - 17:51, Thursday 09 July 2026 (90976)

TF plots corrected to have consistent axis scales

Non-image files attached to this comment
timothy.ohanlon@LIGO.ORG - 18:10, Thursday 09 July 2026 (90977)

LHO data taken from /ligo/svncommon/SusSVN/sus/trunk/BBSS/H1/BS/SAGM1/Data/2026-07-06_1500_tfs. BSC2 ISI was locked and measurements are taken in air

LLO data is taken from /ligo/svncommon/SusSVN/sus/trunk/BBSS/L1/BS/SAGM1/Data/20260706_BBSS_1TOR. BSC2 ISI was fully isolated and the chamber was under vacuum at about 1 Torr.