Displaying report 1-1 of 1.
Reports until 15:58, Monday 13 July 2026
H1 SUS (ISC, SUS)
elenna.capote@LIGO.ORG - posted 15:58, Monday 13 July 2026 (91000)
Replacing/inventorying beamsplitter notches and bandstops

In preparation for locking with the new BBSS, I have taken an inventory of the beamsplitter filters to note where various notches and bandstops are located by suspension stage.

As a reminder, Oli copied over much of the BSFM filters into the BBSS model, 90154.

M1: none as far as I can tell

M2:

M3:

Ibrahim and Oli have measured the BBSS bounce and roll modes to be at 19.80 Hz and 32.09 Hz respectively, 90319.

I'm replacing the bounce and roll bandstops on M2 LOCK and OLDAMP to be centered around these frequencies.

Old foton design string for "NotBR_BS":

ellip("BandStop",4,1.5,40,17.7,17.9)ellip("BandStop",4,3,40,25.7,26.4)gain(1.6788)

New foton design string for "NotBR_BBS":

ellip("BandStop",4,1.5,40,19.7,19.9)ellip("BandStop",4,3,40,32,32.2)gain(1.6788)

 

As a final note, I'm not sure how necessary the BR bandstops are if we have dampers, so we could consider not having any on at all.
 

Displaying report 1-1 of 1.