Reports until 09:59, Wednesday 15 July 2026
H1 SUS
oli.patane@LIGO.ORG - posted 09:59, Wednesday 15 July 2026 - last comment - 17:08, Wednesday 15 July 2026(91044)
BBSS M1 QOSEM satamp compensation filters updated

On Monday Marc updated the BBSS M1 QOSEM satamp (91003). Today I updated the satamp compensation filters. These compensation filters were updated in the FM01 spot in the H1:SUS-BS_M1_OSEMINF_{F1,F2,F3,LF,RT,SD}_{SUM,X_RAW,Y_RAW} filter banks. 

Previous filter: zpk([145e-3],[720e-6],1,"n"), named 0.15:7e-4

New filter: zpk([2.89],[14.4e-3],1,"n"), named 2.9:14e-3

Filters were loaded in and H1SUSBS.txt has been committed as r35492.

**These filters are still currently off because we have not turned the whitening on yet

Comments related to this report
oli.patane@LIGO.ORG - 17:08, Wednesday 15 July 2026 (91057)

I had forgotten to update the satamp compensation filters for the M1 sus watchdogs, so I have now done that. Those are loaded into H1:SUS-BS_M1_WD_OSEMAC_BANDLIM_{F1,F2,F3,LF,RT,SD}_{SUM,X_RAW,Y_RAW} and have been committed to the H1SUSBS.txt filter file as r35497