Displaying report 1-1 of 1.
Reports until 16:31, Friday 17 July 2026
H1 General
anthony.sanchez@LIGO.ORG - posted 16:31, Friday 17 July 2026 (91103)
Friday Ops shift report.

TITLE: 07/17 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:
While the Earthquake slowly rolled through the site CDS took some time to do some updates and restart the Data concentrator 18:02 UTC 
19:48 UTC CDS seemed to recover.

Ryan C and I were wondering why ISC_LOCK wouldn't get to idle. He traced it through ISC_Lock log and found that the ETM X&Y ESD drivers has not recovered from the power outage. Marc went down there to rest the High voltage. But they still are not working properly and there is a very slow barely noticeable increase to the  H1:SUS-ETMX_M0_FASTIMON_F1_OUT16 channles that seems to be growing. Rahul has been contacted and he's going to look at it and he may leave it in safe if it continues to grow in amplitude.

IMC locking team has been trying to get it locked but has been running into chris-crossed-overed settings and are still activley working on locking IMC.


VAC Team have made gains in getting the vacuum pressures to continue to go down, so Pump down Continues!

Jack team is cleaning up for the weekend.

LOG:                                                                                                                                                                                                                                                                          

Start Time System Name Location Lazer_Haz Task Time End
14:38 FAC Kim & co LVEA y Technical Cleaning and resuply 15:09
15:57 FAC Kim LVEA Y Technical Cleaning & ReSupply 17:24
16:12 PSL Jason Control RM N Tweeking Ref Cav and PMC 16:53
16:32 JAC Jennie & Khanh Optics lab/ LVEA Y Looking for power meters. 16:56
17:02 SUS Ryan C Control Rm N Transfer functions on ZMs 17:20
17:04 pcal Tony PCAL lab yes Recovering PCAL lab from Power outage & Setting up new measurement. 17:54
17:20 SUS Rahul, RyanS LVEA Y HAM7 work, ZM alignment, Rahul Out first 18:27
17:21 SEI Jennie LVEA Y Unshutter SPI 17:24
17:29 FAC Mitch LVEA Y Turn OFF Bier Garten cleanroom 17:45
17:47 VAC Gerardo LVEA Y Setup AUX cart by GV2 18:47
18:02 VAC Travis, Gerardo LVEA y Setting up Leak detector 22:53
18:38 CDS Jonathan MSR N DAQ  & Data concentrator restarts 20:09
19:07 Jac Jennie LVEA yes Workign on Jac? 19:20
19:19 JAC Jennie, Khanh LVEA Y JAC table power measurements 20:28
20:54 TCS Madi Optics lab N Workin on lens checks with Eye safe laser. 23:26
21:18 EE Marc EX & EY N pressing the ESD HIgh Voltage rest button 21:58
21:45 Safety Richard LVEA y Checking on the Vacuum Crew status 22:19
22:08 SUS Daniel LVEA y Straining the ZMs 22:14
22:57 CDS Jonathan Remote N Restarting the DAQ stat service 23:22
23:30 JAC Jennie, Khanh LVEA y Cleaning up. 00:00

 

Displaying report 1-1 of 1.