Displaying report 1-1 of 1.
Reports until 12:18, Friday 03 January 2014
H1 AOS
jim.warner@LIGO.ORG - posted 12:18, Friday 03 January 2014 - last comment - 14:50, Monday 06 January 2014(9106)
HEPI PierPod/Chassis issue

Overnight TF's on ITMX HEPI were mostly succesful, but it looks like we have an issue with instrument pods, or associated rack chassis in one of the corners. All of the IPS's and L4C's in corner 3 on this chamber look bad. Power spectra also don't look great.

Non-image files attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 14:50, Monday 06 January 2014 (9116)INS, SEI

This has been resolved. The valve driver cables were swapped on corner 3. Fabrice is working on the data right now to see if we can recover TF.

Displaying report 1-1 of 1.