Reports until 16:44, Friday 24 July 2026
H1 General
anthony.sanchez@LIGO.ORG - posted 16:44, Friday 24 July 2026 (91242)
Mich_Dark_Locked ndscopes

Sheila had me look back to all the time that ALIGN_IFO's channel H1:GRD-ALIGN_IFO_STATE_N was in in MICH_DARK_LOCKED [43].
I made a Statecounter query.

python3 statecounter.py -chan "H1:GRD-ALIGN_IFO_STATE_N" -operator "==" -value 43 -trend "m-trend" -gpsstart "1368975600" -gpsstop "1479398400"

Which returned the output.txt file that now contains all the times that H1:GRD-ALIGN_IFO_STATE_N was in Mich_Dark_Locked. 
It was then easy to use those GPS times in an ndscope to check out the noise on other channels to compare them to today's Mich_Dark_Locked
Comparing that to what we can see in May of 2025 the ASC-AS_A_DC_NSUM has larger fluctuations than todays Mich_Dark .
ASC-AS_B is roughly comparable.

BUT H1:ASC-AS_C_NSUM does seem to have less fluctuations a year ago. 

Images attached to this report