Reports until 16:27, Monday 27 July 2026
H1 ISC
sheila.dwyer@LIGO.ORG - posted 16:27, Monday 27 July 2026 (91266)
IMC servo input offset

Looking at SDFs, on Feb 20th of this year the IMC input offset was changed from -0.38 to -0.07, but not SDF'd.  I don't find anything in the alog from that date that would indicate this was an intentional change.  For now I will revert the change, but we can keep this in mind, or perhaps change it back if someone remembers doing this intentionally.