Displaying report 1-1 of 1.
Reports until 16:37, Monday 06 January 2014
LHO VE
kyle.ryan@LIGO.ORG - posted 16:37, Monday 06 January 2014 - last comment - 09:18, Tuesday 07 January 2014(9123)
Changed VE configuration for HIFO-X
Valved-in IP1,2,5, and 6*Dumped GV7's unpumped gate annulus volume into pump cart*Valved-out YBM turbo*Opened GV7*Valved-in IP12*Dumped GV20's unpumped gate annulus volume into pump cart*Valved-out X-end turbo*opened GV20*Dumped GV5's unpumped gate annulus volume into pump cart*Opened GV5
Comments related to this report
kyle.ryan@LIGO.ORG - 09:18, Tuesday 07 January 2014 (9130)
IP1,2,5 and 6 @ 5000V as of 1630hrs 1/6/2014 (optimal for 1x10-8torr < pressure < 1x10-7torr) 