Displaying report 1-1 of 1.
Reports until 16:44, Tuesday 28 July 2026
H1 ISC
camilla.compton@LIGO.ORG - posted 16:44, Tuesday 28 July 2026 - last comment - 09:25, Wednesday 29 July 2026(91293)
Reworked ITMX Camera can re-attached to X-arm adapter plate

TJ, Camilla, Tyler. WP 13451

The ITMX camera that was removed from A-1C VP4 in 90949 has now been reattached to A-1C VP5. The camera can extender needed to be reduced in thickness, Tyler did this. Camera can D970211-014, camera Balser, lens Rainbow H20X15M  and adjustable post Giotto MH1303, are originally from ITMY, swapped so height would work better. CDS camera was down so we could not yet check and adjust pointing. 

The ITMY reworked camera can is still too wide to for between the VP and Oplev Pier 91160, will now re-work the newer D1300705 type instead which will be more convenient with side access. 

Edits: Originally wrote this as if we installed ITMY camera, we did not, this is ITMX. 

Comments related to this report
camilla.compton@LIGO.ORG - 09:25, Wednesday 29 July 2026 (91305)

After speaking with Richard I re-inserted the guillotine as I think the the camera came loose it's currently in a location where it could fall forward and hit the VP. 

Displaying report 1-1 of 1.