Keita and I took an opportunity while JAC was offline to run all the dark offsets. I ran the usual dark_offsets_exe.py from userapps isc/h1/scripts/dark_offsets
I did not visually check all of them but the ones I compared before and after in SDF looked reasonable.
Some of the whitening gain settings have been set strangely for the vent, so this should help fix that now that we have reset the proper settings.
SDFed, see screenshots.
After we ran, Keita and I realized the whitening settings for POP B were still wrong, so I corrected them and reran the offset for the POP B segments. Added screenshot.