Reports until 16:41, Tuesday 04 August 2026
H1 AOS
khanh.vu@LIGO.ORG - posted 16:41, Tuesday 04 August 2026 (91391)
JAC ASC Loops Closed
Masayuki Nakano, Khanh Vu

We successfully closed all of the JAC ASC loops. Attached below are the outputs from the two wavefront sensors. All of the signals converge to zero within approximately 30 seconds, indicating that the loops are working beautifully. More details will be reported tomorrow.
Images attached to this report