Reports until 18:56, Wednesday 05 August 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 18:56, Wednesday 05 August 2026 (91418)
ECR E2400048 modified preliminary coil driver test results

Here are preliminary pass/fail test results for the modified HAM-A chassis. In 84454 we found out we hadn't done the modifications yet that had been outlined in E2400048.

First I have the results for the newly installed ZM4 and ZM5 coil driver chassis, then the spares, which don't have final results since they aren't assigned to AOSEMs or BOSEMs yet, then the results for the BHD electronics, which aren't being used but have already been installed in the Mechanical Room Mezzanine.

When only one channel is listed as bad, they could actually have an issue or it could just be an error while taking the measurement for that chanel. When multiple channels are bad, that seems more like a chassis problem.

Scripts used to run all of these are in /ligo/svncommon/SusSVN/sus/trunk/electronicstesting/lho_electronics_testing/coildriver/ECR_E2400048/Scripts/, and final results for those who have them are found in /ligo/svncommon/SusSVN/sus/trunk/electronicstesting/lho_electronics_testing/coildriver/ECR_E2400048/Results/.

Rack - Height SUS Stage OSEMs S/N OSEM Type Date tested OutImp (kOhm)
Data looking good?
Comments
ZM4, ZM5              
SUS-C8, U12 ZM4 S2001194 BOSEM 2026-01-29 0p1  yes  
SUS-C8, U11 ZM5 S2001198 BOSEM 2026-01-30 0p1 CH1-4 bad
first pole doesn't get close to 0 phase until we change 0.5 to above 20 Hz
               
Spares              
-- SPARE S2001202 -- 2026-01-29 0p1 yes  
-- SPARE S2001204 -- 2026-01-29 0p1 yes  
-- SPARE S2401019 -- 2026-01-29 0p1 yes  
-- SPARE S2401020 -- 2026-01-29 0p1 yes  
-- SPARE S2001197 -- 2026-01-30 0p1 CH2 bad  
               
-- SPARE S1200609 -- 2026-02-02 1p2
all go up above 1000Hz
 
-- SPARE S1106046 -- 2026-02-09 1p2
all go up above 1000Hz
 
-- SPARE S2500410 -- 2025-10-02 1p2 yes  
-- SPARE S2500412 -- 2025-10-02 1p2 yes  
-- SPARE S2500413 -- 2025-10-02 1p2 yes  
               
Installed for BHD
             
SUS-M2, U42 OM0 M1 F1F2F3SD S2001203 BOSEM 2026-01-30 0p1 CH1 bad  
SUS-M2, U41 OM0 M1 LFRT S2001201 BOSEM 2026-01-30 0p1 CH1,CH4 bad  
SUS-M2, U40 OM0 M3 S2001181 AOSEM 2026-02-02 1p2 CH3 bad  
               
SUS-M2, U38 OBS M1 F1F2F3SD S2001200 BOSEM 2026-01-30 0p1 yes  
SUS-M2, U37 OBS M1 LFRT S2001199 BOSEM 2026-01-30 0p1 yes  
               
SUS-M2, U35 AM1 M1 S2001179 BOSEM 2026-02-09 1p2 yes  
SUS-M2, U34 AM2 M1 S2001178 BOSEM 2026-02-02 1p2 maybe? CH4 bad above 3000Hz  
               
SUS-M2, U32 OMCAB M1 H1V1H2V2 S2001195 AOSEM 2026-01-30 0p1 yes  
SUS-M2, U31 OMCAB M1 H3V3 S2001196 AOSEM 2026-01-30 0p1 yes  
               
SUS-M2, U29 OMA1 M1 S2001177 BOSEM 2026-02-09 1p2 yes  
               
SUS-M2, U27 OMB1 M1 S2001176 BOSEM 2026-02-09 1p2 yes  
               
SUS-M2, U24 OMA2 M1 S1200608 BOSEM 2026-02-09 1p2 ?? CH1-4 bad above 3000Hz  
SUS-M2, U23 OMB2 M1 S1201155 BOSEM 2026-02-02 1p2 ?? CH1-4 bad above 3000Hz  
               
SUS-M2, U21 OMA3 M1 S1201162 BOSEM 2026-02-09 1p2 ?? CH1-4 bad above 3000Hz  
               
SUS-M2, U19 OMB3 M1 S1201165 BOSEM 2026-02-02 1p2 ?? CH1-4 bad above 3000Hz  
Images attached to this report
Non-image files attached to this report