Displaying report 1-1 of 1.
Reports until 21:47, Thursday 06 August 2026
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 21:47, Thursday 06 August 2026 (91433)
SQZ loss measurements

This alog was intended to be a comment on 91436

This morning we continued to use the crane that Camilla and Ryan devised to try to get more reliable power budgeting measurements on the VIP.  Our previous measurements with the power meter held in a hand and hovering over the table consistently showed that we have something like 4% extra losses in HAM7, but they have not been repeatable enough for us to track down the location of the losses.  The crane set up helps us set the angle of the beam profiler head by using a clamp on the post, and also gives us much more steady measurements of power, so we were able to make some progress in identifying the location of losses.  However, we think that the power out of the OPO was drifting by 1-2% during these measurements, which makes the measurements less reliable for finding losses.  

We do think that we have about 0..8% loss at B:L2, where the difficult to align apperture stop is.  This apperture stop catches a rejected beam from B:P1 which is scattered light from the interferometer, so we need to keep it.  We looked for space to move it off the lens mount onto it's own separate mount, but the platform is very crowded with bases and dog clamps in this area, so that would not be an easy solution.  

For the naming of optics see:  D2000021

Displaying report 1-1 of 1.