Reports until 07:36, Tuesday 11 August 2026
H1 General
ryan.crouch@LIGO.ORG - posted 07:36, Tuesday 11 August 2026 - last comment - 08:48, Tuesday 11 August 2026(91474)
OPS Tuesday day shift start

TITLE: 08/11 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
OUTGOING OPERATOR: None
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 9mph Gusts, 4mph 3min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.06 μm/s 
QUICK SUMMARY:

Comments related to this report
ryan.crouch@LIGO.ORG - 08:09, Tuesday 11 August 2026 (91475)SUS

The M2 stage of the BS has been moving a lot since yesterday afternoon ~21:17 UTC, the oplev damping has grown with it.

Images attached to this comment
louis.dartez@LIGO.ORG - 08:42, Tuesday 11 August 2026 (91476)
The BS oplev damping was turned back on by me inadvertently yesterday. The OLDAMP Gain increases happened right as I requested DOWN from the ISC_DRMI guardian. Masayuki and I did notice additional motion on the BS yesterday but we didn't know at the time whether it was due something we did or from something someone else was doing. Now, looking at the timing of the grd state request and confirming by looking at ISC_DRMI.py, I can say that the BS oplev damping was 1.) turned on by accident and 2.) can be / should be turned back off.
Images attached to this comment
elenna.capote@LIGO.ORG - 08:48, Tuesday 11 August 2026 (91477)

I tried to SDF the oplev damping off, see 91267, but I never checked what the guardians do. I recommend we change the guardian code to not engage oplev damping until we can diagnose why it isn't working, specifically, saturating the suspension.