Displaying report 1-1 of 1.
Reports until 15:50, Tuesday 07 January 2014
H1 ISC
stefan.ballmer@LIGO.ORG - posted 15:50, Tuesday 07 January 2014 - last comment - 19:40, Tuesday 07 January 2014(9140)
h1asc updated and recompiled with LLO ASC_MASTER changes
In anticipation of some new changes to the ASC_MASTER library part, I updated it to the latest version from LLO. This includes pitch and yaw outputs for RM1,RM2,OM1,OM2. I updated our h1asc.mdl accordingly, recompiled and restarted it. SVN version number 6759.
Comments related to this report
stefan.ballmer@LIGO.ORG - 18:09, Tuesday 07 January 2014 (9148)
I modified ASC_MASTER library part to route initial green arm alignment signals in and out. This added six new inputs (green arm signals) and twelve new output signals (controls for TMS, PZT1, PZT2, both pitch and yaw).

ASC_MASTER.mdl was checked in to SVN: revision 6761

I also updated h1asc.mdl to deal with the additional in and outputs. For now I connected the twelve RFM IPCs to ISCEX/Y and SUSTMSX/Y. The inputs are still grounded, because the sending models have to be updated first.

h1asc.mdl was checked into SVN: revision 6762

The model was compiled, installed and restarted.

stefan.ballmer@LIGO.ORG - 19:40, Tuesday 07 January 2014 (9149)
I am in the process of updating the ISCEX and ISCEY models to receive the newly sent alignment dither signals for the PZTs.

ALS_END.mdl was updated, and checked into SVN: revision 6763

I am in the process of editing h1iscex.mdl and h1iscey.mdl

More tomorrow.
Displaying report 1-1 of 1.