Reports until 18:30, Wednesday 12 August 2026
H1 SPI
jennifer.wright@LIGO.ORG - posted 18:30, Wednesday 12 August 2026 (91504)
Updated SRC output filters

Jennie W, Jim W,

 

We swapped out the cdsOutput blocks SPI-H23_LO_SRC_CLKMON, SPI-H23_LO_SRC_SINMON, SPI-H23_LO_SRC_COSMON for cdsfilt clocks so we can put in some gains and readout fast channels in medm at this point in the model.

I made these changes in the HJK library part for SPI.

These filters banks are switched on with a gain of 1 but I still need to update the medm screen with the new channels and filter banks.

I also added the channels SPI-H23_LO_SRC_CLK_IN1, SPI-H23_LO_SRC_SIN_IN1, SPI-H23_LO_SRC_COS_IN1 to the DAQ channel list for the spi model.

Images attached to this report