PR2 ringing at 1 Hz

Masayuki, Sheila

When we step the alignment sliders in pitch or yaw on PR2, we see 1 Hz ringing for 15-20 seconds.  

Images attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 14:05, Thursday 13 August 2026 (91527)SUS

Keeping an eye on PR2, took an osem spectra of the inmons and don't see anything abnormal in the suspension right now - but will keep investigating it if these oscillations returns.

Images attached to this comment
masayuki.nakano@LIGO.ORG - 09:08, Friday 14 August 2026 (91538)

This is Sheila

It seems like this ringing at 3Hz has been seen in PR2 for about the last month.  A step of 2urad in pitch causes a ringing with an intial amplitude of 5 urad at 1 Hz that damps down over about 20 seconds.  For yaw the magnitudes are similar, the ringing amplitude is about twice the amplitude of the step.  