oli.patane@LIGO.ORG - posted 14:21, Monday 31 August 2026 (91609)
Rest of test results for HAM-A ECR E2400048 chassis

 Jackie, Oli

Jackie finished retesting the modified HAM-A coil driver chassis that had failed (91418), and they all pass now. Four of the chassis (S1200608, S1201155, S1201162, and S1201165) have the C6 and C20 capacitors as 2.2nF instead of their nominal values, which explains why they deviate from the ideal model at higher frequencies.

S/N Latest date tested Output Impedance (kOhm) SUS Stage OSEMs Rack - Height OSEM Type Looking good? Results saved? Comments
Installed for BHD
S2001178 2026-08-18 1p2 AM2 M1 SUS-M2, U34 BOSEM 2026/08/18: Looking good;
2026/02/02: maybe? CH4 bad above 3000Hz
y Capacitors are nominal
S1200608 2026-08-18 1p2 OMA2 M1 SUS-M2, U24 BOSEM 2026/08/18: Looking good;
2026/02/09: ?? CH1-4 bad above 3000Hz
y ***
S1201155 2026-08-18 1p2 OMB2 M1 SUS-M2, U23 BOSEM 2026/08/18: Looking good;
2026/02/02: CH1-4 bad above 3000Hz
y ***
S1201162 2026-08-18 1p2 OMA3 M1 SUS-M2, U21 BOSEM 2026/08/18: Looking good;
2026/02/09: ?? CH1-4 bad above 3000Hz
y ***
S1201165 2026-08-18 1p2 OMB3 M1 SUS-M2, U19 BOSEM 2026/08/18: Looking good;
2026/02/02: CH1-4 bad above 3000Hz
y ***