anthony.sanchez@LIGO.ORG - posted 16:31, Tuesday 25 August 2026 (91681)
PCAL End X End station Measurement

Caroline and I went to End X with PS4 and followed the instruction on the DCC doc T1500062.
The Current limit red LED was lit up again. I simply adjusted the voltage down a few thousandths of a volt and the current steadied right up at 10V again
The beams were a little offset on the Apature of the RX Sphere when we arrived.  But I did not touch up the alignment this time. I may touch up alignment again next months.
Also we wore gloves this time... that was fun I guess.
 
Commands ran & subsequent output:
anthony.sanchez@cdsws32: python generate_measurement_data.py --WS PS4 --date 2026-08-24
Reading in config file from python file in scripts
../../../Common/O4PSparams.yaml
PS4 rho, kappa, u_rel on 2026-08-24 corrected to ES temperature 299.3 K :
-4.699251194624549 -0.0002694340454223 0.00075040881877916
Copying the scripts into tD directory...
Connected to h1daqnds1
martel run
reading data at start_time:  1471716950
reading data at start_time:  1471717444
reading data at start_time:  1471717888
reading data at start_time:  1471718420
reading data at start_time:  1471719060
reading data at start_time:  1471719400
reading data at start_time:  1471719630
reading data at start_time:  1471720300
reading data at start_time:  1471720660
Ratios: -0.4615405682485709 -0.46591058962067394
writing nds2 data to files
finishing writing
Background Values:
bg1 =        8.879049; Background of TX when WS is at TX
bg2 =        5.011307; Background of WS when WS is at TX
bg3 =        8.896423; Background of TX when WS is at RX
bg4 =        5.129760; Background of WS when WS is at RX
bg5 =        8.965872; Background of TX
bg6 =        0.027675; Background of RX

The uncertainty reported below are Relative Standard Deviation in percent 

Intermediate Ratios
RatioWS_TX_it      = -0.461541;
RatioWS_TX_ot      = -0.465911;
RatioWS_TX_ir      = -0.455518;
RatioWS_TX_or      = -0.460890;
RatioWS_TX_it_unc  = 0.070028;
RatioWS_TX_ot_unc  = 0.067789;
RatioWS_TX_ir_unc  = 0.072976;
RatioWS_TX_or_unc  = 0.075331;
Optical Efficiency
OE_Inner_beam                      = 0.987476;
OE_Outer_beam                      = 0.989974;
Weighted_Optical_Efficiency        = 0.988725;

OE_Inner_beam_unc                  = 0.046927;
OE_Outer_beam_unc                  = 0.047569;
Weighted_Optical_Efficiency_unc    = 0.066821;

Martel Voltage fit:
Gradient      = 1636.904156;
Intercept     = 0.551415;


 Power Imbalance = 0.990620;

Endstation Power sensors to WS ratios::
Ratio_WS_TX                        = -1.078224;
Ratio_WS_RX                        = -1.391522;

Ratio_WS_TX_unc                    = 0.041912;
Ratio_WS_RX_unc                    = 0.038391;

=============================================================
============= Values for Force Coefficients =================
=============================================================

Key Pcal Values :
GS           =      -5.135100; Gold Standard Value in (V/W)             
WS           =      -4.699251; Working Standard Value             

costheta     =      0.988362; Angle of incidence
c            =      299792458.000000; Speed of Light
             
End Station Values : 
TXWS         =        -1.078224; Tx to WS Rel responsivity (V/V)
sigma_TXWS   =        0.000452; Uncertainity of Tx to WS Rel responsivity (V/V)
RXWS         =        -1.391522; Rx to WS Rel responsivity (V/V)
sigma_RXWS   =        0.000534; Uncertainity of Rx to WS Rel responsivity (V/V)

e            =        0.988725; Optical Efficiency
sigma_e      =        0.000661; Uncertainity in Optical Efficiency

Martel Voltage fit : 
Martel_gradient         =        1636.904156; Martel to output channel (C/V)
Martel_intercept   =        0.551415; Intercept of fit of     Martel to output (C/V)

Power Loss Apportion : 
beta          =        0.998895; Ratio between input and output (Beta)  
E_T          =        0.993797; TX Optical efficiency 
sigma_E_T          =        0.000332; Uncertainity in TX Optical efficiency 
E_R          =        0.994896; RX Optical Efficiency 
sigma_E_R          =        0.000332; Uncertainity in RX Optical efficiency 

Force Coefficients : 
FC_TxPD          =        7.900632e-13; TxPD Force Coefficient 
FC_RxPD          =        6.191631e-13; RxPD Force Coefficient 
sigma_FC_TxPD          =        3.624112e-24; TxPD Force Coefficient 
sigma_FC_RxPD          =        2.753947e-24; RxPD Force Coefficient 
data written to ../../measurements/LHO_EndX/tD20260825/ and can be found on the gitlab here


 

 

 

Images attached to this report
Non-image files attached to this report