| POP A LF | POPAIR B LF | REFLAIR A LF | MICH IN1 (REFLAIR A 45 Q) | PRCL IN1 (REFLAIR A 9I) | POPAIR B RF18 | |
| PRMI O4 | 200-400 | 200 | 2-10 | +/-6000 | +/-600 | 80-100 |
| PRMI now | 100 | 6 | 2.5-4 | +/-20 | +/-100 | 5 |
| PRX O4 | 0.5 | |||||
| PRX now | 0.5 |
In order to fix this alignment issue, Sheila, Keita, and I had some different ideas, and it was hard to determine the best path.
Here is the one we tried:
This is the state of the alignment as I am leaving it tonight:
Screenshot attached of all these settings.
Earlier we did some OMC scans and got weird results. We tracked this down to an incorrect DCPD whitening setting. Keita fixed it, and we reran the scans, the carrier peak heights are now correct compared to the blue reference.
Oli tracked down the problem with MC2. All crossovers are fine now and the mode cleaner locks with normal gain settings. They will alog the details.
Centering on POP X DC with PM1 pulls beam off POP A LF
Right now we have an alignment that can bring the beam to both POP A in vac and to the POPAIR diodes on ISCT1 in a PRMI, or with either PRX or MICH locked.
However, the beam was very far off of POP X WFS DC, suggesting PM1 is not well-aligned. I spent a bunch of time trying to move PM1 while keeping the beam on POP A LF and improving the POP X alignment while we are locked on MICH DARK, which brings a lot of light to the POP port.
I gave up on keeping the beam on POP A and instead did much larger moves of PM1, which brought the beam to all four segments of POP X DC and increased the POP X sum. I finally got the beam well enough aligned that I could engage the DC6 centering loop, which aligns PM1 to POP X.
We are now well centered on POP X, but have lost the beam on POP A. PM1 is also unfortunately close to saturation at this alignment.
Here are the PM1 slider values that put the beam on POP X:
P: -868.5, Y: -2076.5
Here are the PM1 slider values that put the beam on POP A LF:
P: 213.5, Y: -258.5
Assuming the sliders have a decent calibration to urad, this is a 1 mrad difference in pitch and 1.8 mrad difference in yaw.
The afternoon of this alog, we had H1:LSC-POP_A_LF_OUT_DQ at 7uW, see attached plot.