Displaying report 1-1 of 1.
Reports until 17:47, Wednesday 08 January 2014
LHO General (SUS)
douglas.cook@LIGO.ORG - posted 17:47, Wednesday 08 January 2014 - last comment - 11:19, Thursday 09 January 2014(9166)
Fiber Pulling Machine updates and Alignments
The fiber pulling machine upper clamp was binding up when we advance the trolly to the end of its stroke after the fiber is pulled. This advanced travel gives you the clearance to allow you to get the fiber assembly out after the fiber is pulled. This issue has been happening more and more recently and causes damage and gross mis-alignments of the translation stages and goniometer mounts. The mounting hardware fit to the fiber clamps was tightly constrained adding to the problem. There is a bit too much wiggle to the mounting stages that were allowing further issues.
Bottom line, I loosened up some of the fit tolerances and coaligned the top and bottom mounts followed up by a beam realignment. I will revisit this in the AM and pull a test fiber. Hopefully we will not have any further issues. I hope to install more robust stages in the near future.
Comments related to this report
betsy.weaver@LIGO.ORG - 11:19, Thursday 09 January 2014 (9177)

Attached is a picture of the top bracket of what would be a fiber holder stuck in the top stage of the fiber puller, when in fact it should have released (hence Doug's hand prepared to catch it during the photo shoot!).  This sticky mating is what Doug fixed.  Currently Travis and Giles are pulling fibers.

Images attached to this comment
Displaying report 1-1 of 1.