Reports until 15:35, Tuesday 01 September 2026
H1 CDS
david.barker@LIGO.ORG - posted 15:35, Tuesday 01 September 2026 - last comment - 16:00, Tuesday 01 September 2026(91775)
sw-lvea-aux failed again 11:09:57

After getting the switch going again at 08:46 it only lasted about 2.5 hours before going down again at 11:16. We immediately did the "pull the cords" power cycle which got it running again at 11:16.

At time of writing (15:34) it has been running for 4.25 hours.

Comments related to this report
david.barker@LIGO.ORG - 16:00, Tuesday 01 September 2026 (91776)

As part of the investigation, sw-lvea-aux's logs is showing port 0/39 is flapping up and down every minute. We suspected this was the new itmx camera's port, so Camilla went into the LVEA and disconnected the ITMX camera. The power cycling of 0/39 stopped at this time (15:15).