Alexa, Kiwamu, Koji, Stefan Today we started with centering the TMS pointing on the ITM using the baffle diodes (with ITMX misaligned) : Baffle PD1: H1:AOS-ITMX_BAFFLEPD_1_POWER maximized: H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 105,5 H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -208.5 Baffle PD4: H1:AOS-ITMX_BAFFLEPD_3_POWER maximized: H1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 174.0 H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -270.0 Center position: 1:SUS-TMSX_M1_OPTICALIGN_P_OFFSET 139.75 H1:SUS-TMSX_M1_OPTICALIGN_Y_OFFSET -239.25 Next we established the visibility into HAM1, i.e. the range of PR3 alignments that result in the x-arm green beam reaching HAM1. The orthogonal slider was left at the initial position. The numbers below are PR3 alignment numbers (i.e. H1:SUS-PR3_M1_OPTICALIGN_P_OFFSET and H1:SUS-PR3_M1_OPTICALIGN_Y_OFFSET): initial position: pit -263.8, yaw -272 disappear up pit -189 disappear down pit -330 (spot visible in ham 2, glow starting at -320) disappear north yaw -188 disappear south yaw -320 on swiss cheese baffle down pit -353 on swiss cheese baffle up pit -176 on swiss cheese baffle south yaw -366 (glow on cam from tower yaw -320) on swiss cheese baffle north yaw -178 center visible: pit -254.5 yaw -254 (using -320 instead of -330 for pit down limit) center swiss cheese baffle: pit -264.5 yaw -272