Displaying report 1-1 of 1.
Reports until 13:13, Tuesday 01 September 2026
H1 SPI
jennifer.wright@LIGO.ORG - posted 13:13, Tuesday 01 September 2026 - last comment - 17:55, Tuesday 01 September 2026(91772)
SPI dark noise measurement

Jennie W, Sina K,

Summary: Yesterday Sina and I did the dark noise measurement for the SPI interferometer and the two SPI optical levers and added in calibration filters based on Jim's measurement of the optical lever to ISI sensor TFs. We also founbd that the dark noise for QPDA has an unexpected shape and so need to do some noise hunting to track this down.

Before doing this we edited the SPI-H23_DIFFDISP matrix to include the factor of 2 that comes from the fact the IFO measures the light round trip between the two platforms and we want it to measure the displacement between them, ie. we divided the first line of coefficients by 2.

Jeff has implemented a new filter bank set for the optical levers called OPLEV CAL FILTERS on the main SPI overview. See image. The output of this filter bank is the optical lever in the qpd basis. The measured calibration will go in 'OPLEV OUT FILTERS' and the output of this filter bank will therefore be in the ISI basis.

We then followed the procedure in T2600019.

 

Images attached to this report
Comments related to this report
jennifer.wright@LIGO.ORG - 17:55, Tuesday 01 September 2026 (91781)

Put the dark offsets on the QPDs back to what they were before our dark noise measurement. Accepted it in sdf.

Images attached to this comment
Displaying report 1-1 of 1.