DAQ DC ethernet stats are being dumped to help search for cause of CRC errors

h1daqdc0 and h1daqdc1 "ethtool -S" stats are being dumped hourly for the DAQ lan interface. Purpose is to gather evidence for the cause of somewhat rare CRC errors (really dropped data blocks) from the real-time system DAQ streams.

Location of the files is /opt/rtcds/userapps/release/cds/common/scripts/daq_eth_stats/archive

The stats gathering services are named daq_eth_stats and are hand-written systemd service and timer units on both systems.

Comments related to this report
erik.vonreis@LIGO.ORG - 16:35, Friday 04 September 2026 (91820)

After several dropped data blocks on DAQ leg one, no error stats on the interfaces changed.  Stat collection has been stopped.