Reports until 07:53, Wednesday 09 September 2026
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 07:53, Wednesday 09 September 2026 (91845)
PSL Status Report (FAMIS #64007)

This is for FAMIS #64007.
Laser Status:
    NPRO output power is 1.846W
    AMP1 output power is 70.55W
    AMP2 output power is 139.4W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 13 days, 21 hr 33 minutes
    Reflected power = 28.32W
    Transmitted power = 104.6W
    PowerSum = 132.9W

FSS:
    It has been locked for 0 days 9 hr and 2 min
    TPD[V] = 0.4572V

ISS:
    The diffracted power is around 4.3%
    Last saturation event was 0 days 9 hours and 52 minutes ago


Possible Issues:
    PMC reflected power is high